Descargar Imprimir esta página

Hayward AquaRite UV LS Manual Del Usuario página 14

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 18
5.3
5.3 Automatic (or with timer):
In this mode the filtration is switched in accordance with a timer that allow to adjust the start and end of the filtration. Timers always operate daily, in
cycles of 24 hours.
To set the ON/OFF times (up to 3 possible time programmable), select with the up/down keys in the timer line you want to change (1-3 ).
The plus/minus keys opens the selected start time field. Set the time with plus/minus keys. Scroll with the up key to the minute field and set it up
with plus/minus keys. To confirm press OK and to cancel press return/scape. To set the OFF timer, proceed accordingly.
See section Filter Cleaning below.
5.4
5.4 Smart*: This mode uses, as a basis, the automatic or timer mode, with its 3 intervals of filtration, but adjusting the filtration time in function of the
water temperature. For that reason 2 parameters of temperature are provided: The maximum temperature, from which on the filtration times will be the
ones from the timer setting. The minimum temperature: below this value the filtration time will be reduced to 5 minutes, which is the minimum working
time. Between these 2 temperatures the filtration times will climb linearly.
Use the plus/minus keys to set the desired minimum and maximum temperatures.
There is an option to activate the antifreeze mode in which the filtration will start if the water temperature is below 2° C.
To set the ON/OFF times (up to 3 possible time programmable), follow the instructions of the Automatic Mode.
See section Filter Cleaning below.
* Note: Mode only visible if the option to use temperature probe and/or heating is activated in the "Installer Menu".
5.5
5.5 Timed heating with option of climatization*: This mode acts equally to the automatic mode, but besides it includes the option to work on a
relay to control the temperature. The desired temperature is set in this menu, and the system works with a hysteresis of 1 degree (example: the
setting temperature is 23° C, the system will activate itself when the temperature goes below 22° C and will not stop before it passes 23° C).
Use the plus/minus keys to set the desired temperatures and ON/OFF of the Heating.
Clima OFF: The heating only works within the set filtration periods.
Clima ON: Keeps the filtration working when the filtration period is finished if the water temperature is below the setting temperature. When the
setting temperature is reached the filtration and the heating will stop and will not switch on till the next programmed filtration period.
To set the ON/OFF times (up to 3 possible time programmable), follow the instructions of the Automatic Mode.
See section Filter Cleaning below.
* Note: Mode only visible if the option to use temperature probe and/or heating is activated in the "Installer Menu".
5.6
5.6 Intelligent*: In this mode the user has 2 working parameters to guaranty the desired water temperature with a minimum of filtration hours:
You select the desired water temperature and the minimum filtration time (minimum of 2 hours and maximum of 24 hours). The device divides
the selected "minimum filtration time" in 12 fragments which start up every 2 hours. If one of these fragments finishes, without the temperature
reaching the desired level, the filtration/heating continues until the desired temperature is accomplished. In order to keep the filtration-electricity-
cost to a minimum, this additional filtration time is subtracted from the following fragments of the "minimum filtration time". The first 10 minutes
of each fragment will not be subtracted.
Example (see diagram): Minimum temperature = 28°C and minimum filtration time = 12 hours.
The desired water temperature and the minimum filtration time is set with the plus/minus keys .
See section Filter Cleaning below.
10 min
28ºC
ON
OFF
0h
1h
2h
3h
4h
DIAGRAM INTELLIGENT MODE
* Note: Mode only visible if the option to use temperature probe and/or heating is activated in the "Installer Menu".
5.7
5.7 Filter cleaning mode (and pool cleanig by sucction): From this menu (accessible from any Filtration mode) It can be easily performed
a backwashing cleaning of the sand filter. Activating this menu from any filtration mode (Manual, Automatic, Heating, Smart, Intelligent), will
disconnect electrolysis/hydrolysis cell. Then proceed as follows:
• Put the filter pump OFF with plus/minus keys.
• Place the filtration pump valve in backwashing cleaning position.
• Put back ON in the filtration pump. Control the time that lasted the backwash cleaning on the clock display. Make sure it has made adequate and
complete backwash of your filter.
• When finished the backwashing cleaning, again turn OFF the filtration pump and put back the valve in the filtering position. If you wish, now you
can perform a rinse cycle.
• Proceed as backwashing cleaning, this time placing the filtration pump valve in the rinsing position.
• When leaving the Filter Cleaning menu, the system will be back to the previous programmed mode.
5.1 FILTRATION / Automatic mode
5.2 FILTRATION / Smart mode
5.3 FILTRATION / Heating mode
5.4 FILTRATION / Intelligent mode
28ºC
27ºC
5h
6h
7h
8h
9h
10h
5.5 FILTRATION / Filter cleaning
27ºC
11h
12h
13h
14h
15h
16h
14
28ºC
17h
18h
19h
20h
21h
22h
23h
24h

Publicidad

loading