CAUTION!
The device operates properly only when the pressure in the gas distribution
grid is between the values provided in the table below for various gas types.
Application of gas categories in different countries
Country of destination
FR-BE
IT-ES-PT-IE-GB-GR-CZ-SK
FI-SI-NO-HR-TR-LT-LV-EE-
RO-BG
AT-CH
DE
NL
IS
CY-MT
HU-CY-MT
PL-LU
DK
SE
CAUTION!
In case of deviation from the above mentioned values, there is no guarantee of proper
functioning and correct activation of the device. Ask the gas installer to check the gas
supply (inspect the gas installation, valves and possibly pressure regulators), if
necessary consult the gas supplier.
Gas supply pressure
20/25; 28-30/37 mbar
20; 28-30/37 mbar
20; 30 mbar
20; 50 mbar
20; 50 mbar
25; 30 mbar
30 mbar
28-30/37 mbar
30 mbar
20 mbar
8; 20; 30 mbar
8; 20; 30 mbar
Category
II2E+3+
II2H3+
II2H3B/P
II2H3B/P
II2ELL3B/P
II2L3B/P
I3B/P
I3+
I3B/P
I2E
III1a2H3B/P
III1ab2H3B/P
- 35 -