Operation
Setting the parameters in the working window
The cursor (31) indicates which parameter can be set. After the device has been switched on, the cursor is in
the "SPEED" position.
The following parameters can be selected with the Select key (28) in the working window and their values can be
changed with the Up key (29) and the Down key (27).
Setting the output volume
The output volume and pre-heating time can be matched according to the seam form.
• Default setting on the display
– Press the Select key (28) to move the cursor to the "SPEED" position.
– Set the maximum output value (60 to 100%) with the Up key (29) or the Down key (27) (indicated by the drive
display bar (22))
• Fine adjustment during the welding process
– The output volume can be reduced from the maximum set output value (e.g., 85%) to the minimum by turning
the potentiometer (3)
The output volume depends on the thickness of the welding rod. If the output is too high when the output display reads
"60" and the potentiometer is set to "minimum", change to the next smallest welding rod thickness.