Closing input
To use the input as a closing command, you need to set the
SiC = cLoS
parameter
Connect a normally open button to terminals L5 and L6
L11
L10
L9
L8
L7
L6
L5
8.6 - FLASHING / WARNING LIGHT
OUTPUT
The PD22 control unit has a configurable lights output 24Vdc-3W
that can be used for a flashing light or a warning light.
C
the input is configured by default as flashing light
SPiA
FLSh
(parameter
=
To configure the output as warning light, change the
SPiA
settings of the
parameter
The flashing light is enabled during opening and closing phases
with the same flashing frequency, while the warning light flashes
at 2 Hz during opening phase, at 4 Hz during closing phase and
remains lit during the pause.
Connect the cables to terminals L10 (+) and L11 (-) of the control
unit.
-
+
L11
L10
L9
L8
L7
L6

8.7 - COURTESY LIGHT

ATRIS is equipped with a built-in courtesy light that stays lit during
opening and closing phases for a period of time that can be set
from parameter LUCi (default = 1 minute)
NOTE: if automatic closing is enabled the courtesy light remains
on during the pause and starts flashing in the last 20 seconds
before the reclosing phase. In the last 20 seconds before the
reclosing phase, the device also emits BEEPS.
L4
L3
L2
L1
).
L5
L4
L3
L2
L1

8.8 - ANTENNA

ATRIS comes with an already connected internal antenna.
If the radio range is not enough, we recommend you to use the
external antenna code 19A001.
Remove the internal antenna connected to terminal L1.
Connect the antenna hot pole to terminal L1 (ANT) of the
control unit and the shield to terminal L2 (ANT-).
L11
L10
L9
L8
L7
L6

8.9 - POWER SUPPLY

The control unit must be fed by a 230V-50Hz electric line,
protected by a differential magnetothermal switch complying with
the law provisions in force.
Connect the plug of the device to the power line.

8.10 - BATTERY POWER

If you want the device to function even in the event of a
black-out, you can connect the B-PACK (accessory code 161212)
or ECO-LOGIC (accessory code 28A034) battery pack.
Connect the B-PACK or ECO-LOGIC battery pack connector to the
BATTERY terminals of the control unit.
m
ATTENTION: when using the battery or the ECO-LOGIC
device, you need to enable the ENERGY SAVING function
En.SA
Si
(parameter
=

8.11 - PLUG IN RECEIVER

PD22 control unit is suitable for plugging in a MR receiver having
a high-sensitivity super-heterodyne architecture.
MR module receiver is provided with 4 channels and each of
them is suitable for a command of PD22 control unit:
g
• CHANNEL 1
START
g
• CHANNEL 2
PARTIAL OPENING FOR VENTILATION
g
• CHANNEL 3
STOP
g
• CHANNEL 4
COURTESY LIGHT
NOTE: Before programming 4 channels and function logics
read carefully the instructions of MR.