ENGLISH
~
AC Measurement
-
Negative DC Value
O.L.
Overload: Range Exceeded
Low Battery
V
Voltage Measurement
Ω
Resistance in Ohms
k
Kilo 10
DC Voltage Measurement
Range
1.0V ~ 1000V
-1.0V ~ -1000V
Overload Protection:
Input Impedance (Nominal): > 10MΩ, < 100pF
AC Voltage Measurement
Range
1.2V ˜ 750V
Overload Protection:
Frequency Response:
Response:
Averaging
Input Impedance (Nominal): > 10MΩ, < 100pF
Input Impedance (Low Z) > 3kΩ, < 200pF, up to 600V RMS
AC Current Measurement
Range
0.9A ~ 200A
Overload Protection:
• Current:
200A
45 to 1kHz
Frequency:
Averaging
Response:
Resistance Measurement
Range
Resolution
400Ω ˜ 4MΩ
0.1Ω ˜ 0.001MΩ
40MΩ
0.01MΩ
Overload Protection:
Continuity Test
Overload Protection
600V RMS
Overload Protection:
Non Contact Voltage Detector
On Voltage
Appx. 25V AC and above
SYMBOLS USED ON LCD
3
ELECTRICAL SPECIFICATIONS
Resolution
0.001V ~ 1V
0.001V ~ 1V
1000V
Resolution
0.001 ~ 1V
750V RMS
45 to 400 Hz
Resolution
0.1A
Accuracy
± (1.0% + 4 digits)
± (2.0% + 4 digits)
600V RMS
Open Circuit Voltage
< 0.44V
600V RMS
DC Measurement
AT
Auto Range Active
Apo
Auto Power-Off Active
Hold Active
HOLD
A
Current in Amps
Continuity Test
M
Mega 10
Accuracy
± (1.0% + 4 digits)
Accuracy
± (1.5% + 3 digits)
Accuracy
± (2.0% + 8 digits)
Threshold (Appx.)
< 40Ω
6