Electrical Specifications - Klein Tools CL210E Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Function
AC voltage
(V AC)
DC Voltage
(V DC)
Input impedance: 10 MΩ
Frequency range: 45 to 400 Hz
Maximum input: 600 V AC RMS or 600 V DC
AC current
(A AC)
Frequency range: 50 to 60 Hz
Resistance
Maximum input: 600 V AC RMS or 600 V DC
Temperature
OTHER MEASUREMENT APPLICATIONS
Maximum input: 600 V AC RMS or 600 V DC
• Continuity check: Audible signal <10 Ω, max. current 1.5 mA
• Sampling frequency: 3 samples per second
• Auto power off: After ~15 minutes of inactivity
• Overload: 'OL' indicated on display
• Polarity: '-' on the display indicates negative polarity
• Display: 3 ½ digit, 2000 count LCD

ELECTRICAL SPECIFICATIONS

Range
200.0 mV
2.000 V
20.00 V
200.0 V
600 V
200.0 mV
2.000 V
20.00 V
200.0 V
600 V
2.000 A
20.00 A
200.0 A
400 A
200.0 Ω
2.000 KΩ
20.00 KΩ
200.0 KΩ
2.000 MΩ
20.00 MΩ
-40°F to 1,832°F
-40°C to 1,000°C
Resolution
0.1 mV
1 mV
10 mV
100 mV
1V
0.1 mV
1 mV
10 mV
100 mV
1V
1 mA
10 mA
100 mA
1A
0.1 Ω
1 Ω
10 Ω
100 Ω
1 KΩ
10 KΩ
≤0°F ±(2.8% + 12 digits)
1°F
1°C
Accuracy
±(2.5% + 10 digits)
±(2.0% + 5 digits)
±(1.0% + 8 digits)
±(1.0% + 3 digits)
±(2.5% + 30 digits)
±(2.0% + 10 digits)
±(1.2% + 5 digits)
±(1.2% + 3 digits)
±(2.0% + 5 digits)
>0°F ±(2.8% + 6 digits)
±(2.8% + 6 digits)
3

Publicidad

Tabla de contenido
loading