Function
AC Voltage
(V AC)
DC Voltage
(V DC)
Input Impedance: 10MΩ
Frequency Range: 45 to 400Hz
Maximum Input: 600V AC RMS or 600V DC
AC Current
(A AC)
Frequency Range: 50 to 60Hz
Resistance
Maximum Input: 600V AC RMS or 600V DC
Temperature
°F
Temperature
°C
OTHER MEASUREMENT APPLICATIONS
Maximum Input: 600V AC RMS or 600V DC
• Continuity Check: Audible signal <10Ω, max current 1.5mA
• Sampling Frequency: 3 samples per second
• Overload: "OL" indicated on display
• Polarity: "-" on display indicates negative polarity
• Display: 3 ½ digit, 2000 Count LCD
ELECTRICAL SPECIFICATIONS
Range
200.0mV
2.000V
20.00V
200.0V
600V
200.0mV
2.000V
20.00V
200.0V
600V
2.000A
20.00A
200.0A
400A
200.0Ω
2.000KΩ
20.00kΩ
200.0kΩ
2.000MΩ
20.00MΩ
-40° to 10°F
11° to 1832°F
-40° to -12°C
-11° to -1000°C
Resolution
0.1mV
1mV
10mV
100mV
1V
0.1mV
1mV
10mV
100mV
1V
1mA
10mA
100mA
1A
0.1Ω
1Ω
10Ω
100Ω
1kΩ
10kΩ
1°F
1°C
Accuracy
±(2.5% + 10 digits)
±(2.0% + 5 digits)
±(1.0% + 8 digits)
±(1.0% + 3 digits)
±(2.5% + 30 digits)
±(2.0% + 10 digits)
±(1.2% + 5 digits)
±(1.2% + 3 digits)
±(2.0% + 5 digits)
±(1.2% + 7 digits)
±(1.2% + 6 digits)
±(1.2% + 4 digits)
±(1.2% + 3 digits)
3