DC Voltage Measurement
Range
400mV ˜ ˜ 400V
1000V
Overload Protection:
AC Voltage Measurement
Range
400mV ˜ ˜ 750V
Overload Protection:
Frequency Response:
Minimum Voltage for Frequency Measurement:
Response:
Averaging
DC Current Measurement
Range
400µA
2000µA
Overload Protection:
600V RMS
Voltage:
•
2000µA
Current:
•
AC Current Measurement
Range
400µA
2000µA
40A
400A
Overload Protection:
600V RMS
Voltage:
•
2000µA
Current:
•
Frequency:
45 to 400Hz
Minimum Current for Frequency Measurement:
Response:
Averaging
Resistance Measurement
Range
400 Ω ˜ 4M
˜ 4M
Ω
˜
40M Ω
Overload Protection:
Capacitance Measurement
Range
40nF ˜ 4000µF
˜ 4000µF
˜
Overload Protection:
Frequency Measurement
Range
99.99Hz ˜ 499.9kHz
˜ 499.9kHz
˜
Overload Protection:
ELECTRICAL SPECIFICATIONS
Resolution
0.1mV ˜ ˜ 0.1V
1V
1000V
Resolution
0.1mV ˜ ˜ 1V
750V RMS
40 to 400 Hz
Resolution
0.1µA
1µA
Resolution
0.1µA
1µA
0.01A
0.1A
Resolution
0.1 Ω ˜ 0.001M
˜ 0.001M
˜
0.01M Ω
600V RMS
Resolution
0.01nF ˜ 1µF
˜ 1µF
˜
600V RMS
Resolution
0.01Hz ˜ 0.1kHz
600V RMS
Accuracy
± (0.5% + 4 digits)
± (0.8% + 10 digits)
Accuracy
± (2.0% + 5 digits)
200mV
Accuracy
± (1.2% + 3 digits)
Accuracy
± (2.0% + 5 digits)
± (1.5% + 5 digits)
± (2.9% + 15 digits)
± (1.9% + 8 digits)
400µA or 20A
Accuracy
± (1.0% + 4 digits)
Ω
± (2.0% + 4 digits)
Accuracy
± (3.5% + 6 digits)
Accuracy
˜ 0.1kHz
± (0.1% + 4 digits)
˜
Sensitivity:
1.8V RMS