Drilling holes
Use transfer punch to mark hole centers. Hold rail in
alignment, until secured, with spring or "C" clamps
when marking and drilling holes. The first fastener must
be 50 mm to rail end or less.
Threadlocking fasteners
Always use threadlocking solution or locknuts.
Preventing corrosion between fasteners and rail
Use an anti corrosion paste on the fastener head to prevent galvanic corrosion between fastener and rail. Do not
use for nuts on fastener.
The R27 rail must be connected to the lightning protection system, in compliance with current regulations.
End stop assembly instructions
Using IN1642.CLEAR removable endstops
They allow user to easily remove trolley assemblies for storage away from the elements and for switching trolley
assemblies from one rail to another. The end fitting can be easily removed and inserted, thanks to its spring pin.
NOTE!: Be sure the first rail mounting fastener is located within 50 mm of the rail end.
16
IN1643.CLEAR
IN1643
IN1642.CLEAR
ENGLISH
IN1650.CLEAR
IN1650
24/07/20