Problem
Diagnosis
Your appliance is not
powered up.
The appliance is not
Your appliance is not turned
working.
on.
The "Window detection"
function is not activated.
The appliance continues
The correct operating
to heat, even though a
conditions for the window
window is open.
opening/closure detection
function have not been met.
The appliance does
The correct operating
not start to heat again,
conditions for the window
although a window has
opening/closure detection
been closed.
function have not been met.
The remote control does
The remote control is
not allow operations.
locked.
Communication problems
Remote control and/or radio
between remote control
frequency communication
and appliance.
problem.
Pairing has been lost fol-
The remote control and the
lowing a power failure.
appliance have to be reset.
76
Procedure
Check your appliance is properly
connected and powered (see
chapter 2.2).
Check the remote control is properly
turned on (see chapter 5.1).
Check the pilot wire unit is not
sending a load shedding stop order.
Activate the function (see chapter
5.5, parameter 1).
See chapter 5.4
See chapter 5.4
Disable key locking (see chapter
5.1).
Check the
icon is present (paired
appliance).
Check that the LED changes colour
according to the commands sent.
Check your appliance is not control-
led by a pilot wire unit.
If checks are positive: remove the
control batteries for 10 minutes then
replace the batteries.
• Reset the remote control in the
advanced parameters (see chapter
5.5 parameter 9).
• Reset the appliance by pressing
10 seconds on the LED. The LED
flashes magenta quickly to confirm
the reset.
• After it is pressed, the LED returns
to fixed magenta. Turn on the remote
control and start the pairing process.
40016512
Problem
Diagnosis
The battery level indicator
Batteries drained.
on your remote control
is displayed.
The remote control is off.
The back-lighting on the
No display.
remote control screen is off.
The remote control screen
is on standby.
The time flashes.
Time and date setting not
done.
The temperature setting
There is a discrepancy in
does not match the tem-
the measurement made by
perature observed in the
the temperature probe.
room.
Remote control broken.
Your appliance remains on
the last command received.
PILOT WIRE
Problem
Diagnosis
The pilot wire is not
connected correctly.
The appliance no longer
replies to commands from
the pilot wire.
Your remote control is no
longer set to accept pilot
wire operation.
The room temperature
The pilot wire may be
does not match the pre-
connected to a program-
ferred temperature level
ming control unit which
on the remote control.
takes over from the remote
control (e.g.: sending an
Eco mode order from the
control unit, while the
control is set on Comfort).
11/2017
Procedure
Change batteries (see chapter 8.3).
Long press on
.
Press a key to turn it on again.
Press a key to turn it on again.
Set time and date (see chapter 4.1).
Calibrate your remote control (see
chapter 5.3) to align the tempera-
ture measured in the room by the
appliance, and that measured by your
thermometer.
• Reset the appliance by pressing
10 seconds on the LED. The LED
flashes magenta quickly to confirm
the reset.
• Your appliance is waiting to be
paired and to start heating again.
Procedure
Check the pilot wire connection (see
chapter 2.2).
Check the remote control is in
Comfort mode.
Activate the pilot wire function on
your remote control (see chapter 5.5,
parameter 3).
Deactivate the pilot ware in advanced
parameters (see chapter 5.5 para-
meter 3) so that the remote control
continues to operate your appliance.