Pin Entry Modes - Steren SEG-150 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Where:
60 to indicate that it will set the security block.
1 is the preset mode. After 10 wrong codes will lock the door for 60 seconds.
5-10 if you select a number between 5 and 10 will be the number of failed
attempts that are allowed before locking the door for 15 minutes.
# to confirm.
If you need to operate the door during block the need to enter the following
sequence:
Administrator PIN + # + 9
If you want to delete all security settings block, so that the door is not blocked
in any case, enter the following sequence:
60 + 00 + #

PIN entry modes

There are two types of PIN entry, manual and automatic. In manual mode,
after entering the PIN user must press #. In this mode, the PIN can be 4 to 8
digits. In automatic mode, the user will not have to press # but all PINs must be
the same number of digits than the master code. To select between these two
modes press the following sequence in programing mode:
70 + 1 or 2 + #
19

Hide quick links:

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido