Exit Button - Steren SEG-150 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Exit Button

If you need an exit button, you can configure it in different ways so that better
suits your needs. This button will open the door without the need to enter a
code or read a card. To set the start button you must enter the following
sequence of digits:
90 + 1, 2, 4 or 5 + 0 or 1-99 + #
Where:
90 to indicate that it will set the exit button.
1 for momentary mode with no tone. The door will open as soon as you press
the button and it momentarily shut down after the time delay.
2 for momentary mode with tone. The system will emit a warning tone until it
reaches the delay time.
4 for contact mode with no tone. The start button must be held down until reach
the delay time.
5 for contact mode tone. Sounds a tone until it reaches the delay time.
0 to indicate that the door will open immediately after pressing the start button
1-99 is the delay interval (in seconds) to be scheduled between button press
and the opening of the door.
# to confirm.
22

Hide quick links:

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido