Ball Nozzle; Shutting Down; Wintering Over - BADU JET Turbo Pro Traducción De Las Instrucciones Para El Manejo Originales

Ocultar thumbs Ver también para JET Turbo Pro:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 262
6.2.3

Ball nozzle

The nozzle (42) alignment can be set using the pipe Ø25 included
in the scope of supply. The direction of the ball nozzle is
individually adjustable. The nozzle (42) must usually be set
horizontally.
If it is stiff, the nozzle (42) can be loosened and adjusted by
undoing the three Phillips tapping screws (46) with a suitable
screwdriver. Insert the Phillips screwdriver through the respective
guide hole on the stainless steel panel (3x) and push through to
the screw.
6.3

Shutting down

1.
Switch off the system and disconnect from the mains.
2.
Lower the water level in the swimming pool to the lower edge
of the panel.
6.3.1

Wintering over

For outdoor countercurrent systems which could be endangered
by frost during the winter.
Active overwintering:
Formation of ice can be prevented by circulating the water by
connecting a filter pump to the nozzle (c).
Passive overwintering:
1.
Lower the water level at least to the lower edge of the panel.
2.
Pull out the complete drive unit (including the motor) after
loosening the 10 tapping screws (37) and store in a dry room.
3.
It is also recommended to remove the stainless steel panel
(55) to protect it from getting dirty during the winter months.
08|2020
Commissioning/Decommissioning
EN 43