Locking Programming Fig; Refitting Covers Fig; Technical Specifications; Dimensions - SOMFY DEXXO OPTIMO RTS Manual De Instalación

Ocultar thumbs Ver también para DEXXO OPTIMO RTS:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 39
Dexxo Optimo RTS

10 LOCKING PROGRAMMING FIG. 30

The keypad must be locked to ensure the safety of the end-users.
Non-observance of this instruction can result in serious injury to persons, e.g. when
trapped by a door.
Pressing the "SET", "+", "-" buttons:
- start by pressing "SET".
- the "+" and "-" buttons must be pressed simultaneously within 2 seconds
Pressing the "SET" button then no longer has any effect.
The remote control memorising functions ("PROG" button) and forced mode operation ("+", "-"
buttons) remain possible.
To access programming mode once again, repeat the same procedure.

11 REFITTING COVERS FIG. 31

Position the aerial and fit the covers.
To ensure proper remote control range, the aerial must be fitted in one of the
two positions shown in Fig. 31.
12 TECHNICAL SPECIFICATIONS
BASIC TECHNICAL CHARACTERISTICS
Mains supply
Standby
Max.
power
consumption
Operation
Peak force
Traction force
(1)
Starting force
Use
Max. speed
Programming interface
Operating temperature
Travel end limits
Electrical insulation
Built in lighting
Radio frequency
Number of channels that can be memorised 32
CONNECTIONS
Type
Safety input
Compatibility
Pedestrian door safety input
Wired control input
Orange light output
Accessory power supply output
Remote aerial input
Backup battery input
Autonomy
Charge time
OPERATION
Forced operation mode
Independent lighting control
Lighting time delay (a er movement)
Amber light pre-warning
Built-in obstacle detection
Copyright © 2017 Somfy SAS. All rights reserved
WARNING
230 V - 50 Hz
4 W
120  W
800 N
650 N
Intensive use
14 cm/s
4 buttons - 4 indicator lights
- 20 ° C / + 60 ° C - indoor dry - IP 20
Mechanical
stopper
at
Memorized end limit position at closing
Class 2: double insulation
led G45 24V / 4W ; BA15s socket
433,42 MHz
< 10 mW
Dry contact: NC
Photoelectric TX/RX cells
Dry contact: NC
Dry contact: NO
24 V - 15 W with built in flashing control
24 V - 500 mA max
Yes: RTS aerial compatible (Réf. 2400472)
Yes: battery pack compatible (Réf. 9001001)
24 hours; 5 to 10 cycles depending on door
48 hours
Pressing the motor control button
Yes for built-in lighting
Fixed 60 s
2 s automatic if light connected
Adjustable sensitivity: 4 levels
Operation when an obstacle is detected
Progressive start up
Opening speed
Closing speed
Closure approach speed
(1)
Maximum load for motor to start and drive door for at least 5 cm (according to RAL-GZ
definition).

12.1 Dimensions

171 min
63,6
opening
Full re-opening
Yes
Set: 14 cm/s (max.)
Set: 12 cm/s (max.)
Programmable: does not slow down,
short
slowdown
long slowdown zone (50 cm)
Overall length: 3,295 / 3,895
Longueur hors tout : 3295 / 3895
Available travel: 2,555 / 3,155
Course utile : 2555 / 3155
140
Fixation: 2,982 / 3,582
Fixation : 2981,7 / 3581,7
Rail: 2,900 / 3,500
Rail : 2900 / 3500
Overall length: 3,153 / 3,753
Longueur hors tout : 3153 / 3753
Rail : 2,900 / 3,500
Rail : 2900 / 3500
EN
zone
(30
cm),
313,6
254,1
404,2
112,2
224,4
7