CV
Explanation
1
Address 1 (main address)
2
Minimum speed (Vmin)
3
Acceleration delay (AV)
4
Braking delay (BV)
5
Maximum speed (Vmax)
8
Decoder reset (default or factory setting)
17
Address 3 (2nd consecutive address)
18
Address 4 (3rd consecutive address)
Braking mode:
always 0, not occupied
16 : DC voltage, polarity against the direction
27
of travel
32: DC voltage, polarity with the direction
of travel
48: always brake (fx/mfx)
* () = 6021 Control Unit {} = the values entered are multiplied times "x" (factor).
CV Table for fx (MM)
Values
Default
60949=24
1-255 (1 - 80)*
60948=72
60949=1
1-255 (1 - 80)*
60948=5
1-255 (1 - 80)*
60949=18
[0,00s - 20,00sec.]
60948=32
1-255 (1 - 80)*
60949=15
[0,00s - 20,00s]
60948=17
1-255 (1 - 63)*
255
{x4}
8
1-255 (1 - 80)*
254
1-255 (1 - 80)*
253
0
16
32
48
Notes
Address is always active and is not subject
to CV 49.
Speed at the smallest speed level. Value
must be smaller than Vmax, CV 5.
CV value multiplied by 0.25 gives the time
from complete stop to maximum speed.
CV value multiplied by 0.25 gives the time of
the braking delay.
Speed at the highest speed level. Value
must be greater than CV 2.
-
Value is not written.
Address can be deactivated/activated
subject to CV 49.
Address can be deactivated/activated
subject to CV 49.
Braking subject to direction:
- 16 normal DCC properties
48
- 32 inverse DCC properties
Braking not subject to direction:
- 48: fx/mfx properties
37