6.3.2 Standard selection
The inverter is delivered without a specific standard selected. It is necessary to parameter the
inverter before its commissioning according to existing standards in your country
Example : AS4777 for Australia
The selection of the operating standard is possible from the settings/flow management.
The Italian standard IEC 0-21 requires for all inverters that inject power into the public grid a self-test
function in accordance with IEC 0-21. This self-test is possible from the button
of the test, the results are recordable.
FR
6.3.3 Battery selection
FR
EN
ES
6.3.3.1
IT
Check the compatibility of the battery with the IMEON inverter (according to the documentation
available on our website: https://imeon-energy.co.uk/download-center/).
The commissioning procedure for batteries may differ from one manufacturer to another, refer
to the battery manufacturer's documentation.
In OS.ONE, select the used accumulator from the drop-down menu and click "OK".
6.3.3.2
The battery installed must be compatible with the IMEON. Please refer to the IMEON
ENERGY website (https://imeon-energy.com) for a list of compatible batteries.
The battery commissioning procedure may differ from manufacturer to manufacturer, refer to
the manufacturer's battery documentation.
1. For Lithium battery using a CAN communication, connect the RJ45
connector wired as presented on figure (stranded cable, minimum
category 6A is recommended) on IMEON‟s CAN port.
Refer to the battery documentation for connection on battery side.
2. Select the battery from the list, then press "OK".
3. Start the battery physically.
4. Once communication is established, the battery will be started automatically.
Note: Inverters with a software version lower than 1.7.7.7 do not benefit from this feature. Please
update your inverter.
5. When the "Battery operating" message is displayed, the battery is operational and communicates
with IMEON.
78
IMEON INVERTER
Lead-acid/supercapacitor batteries
Use of a lithium battery
IMEON_installation_guide_rev.D.5
. At the end
Figure 1 - RJ45
connector