Warning
• Active medical devices are subject to special EMC precautions and they must be installed and used in accordance with
these guidelines.
• Electromagnetic fields can affect the performance of the device, so other equipment used near the equipment must meet
the appropriate EMC requirements. Mobile phones, X-rays, or MRI devices are possible interference sources, as they
emit high-intensity electromagnetic radiation.
• The use of ACCESSORIES, transducers and cables other than those specified, with the exception of transducers and
cables sold by the MANUFACTURER of the the device as replacement parts for internal components, may result in
increased EMISSIONS or decreased IMMUNITY of the ME EQUIPMENT or ME SYSTEM.
• The device should not be used when they are close to or stacked with other equipment, if necessary, please observe and
verify that they can operate normally in the configurations.
• Devices or systems may still be interfered by other equipment, even if other equipment meets the requirements of the
corresponding national standard.
• The device requires special precautions for electromagnetic compatibility (EMC) and requires qualified personnel to
install and use in accordance with the EMC information provided below.
• The device should not contact the pins of connectors marked with an ESD warning symbol, unless electrostatic discharge
precautions are used, the device should not connect to these connectors.
• In order to avoid the accumulation of electrostatic charge, it is recommended to store, maintain and use the equipment at
a relative humidity of 30% or more. The floor should be covered with ESD dissipated carpets or similar materials. In the
use of the components, non-synthetic clothing should be wore.
• In order to prevent electrostatic discharging to the ESD-sensitive parts of the device, the personnel should contact the
metal frame of the components or the large metal objects near the device. When using the device, especially when it is
possible to contact the ESD-sensitive parts of the device, the operator should wear a grounded bracelet designed for
ESD-sensitive devices. For more information on proper use, please refer to the instructions provided with the bracelet.
• All potential users are advised to understand the ESD warning symbols and receive training on ESD precautions.
• The most basic content of the ESD precautionary procedure training should include an introduction to electrostatic charge
physics, voltage level in the conventional case, and damage to the electronic components when the operator with elec-
trostatic charge contacts them. In addition, the methods for preventing electrostatic buildup, and the manner and reasons
ENGLISH