Tubular motors have an electronic limit switch system with an encoder. This sy-
stem ensures great reliability and precision in keeping the positions. Limit switch
regulation is performed simply with the remote control. During setting, the motor
moves only as long as the up or down button is pressed, stopping when the button
is released.
At the end of setting, press either the up or down button briefly to move the motor.
After setting the remote control, it's necessary to set first the closing position!
For cassette-awnings, hold the button pressed until the motor stops automatically
on the closing position. For open awnings, hold the button pressed and drive until
the necessary closing position.
Notes: - If the awning is completely closed, you have firstly to open it by around
20 cm.
- Because the correct rotation direction will be identified only after the closing po-
sition is set, to close the awning, during setting the closing position, it's sometimes
necessary to use the "down" button.
To set the closing position, hold pressed the "stop" button (around 2 sec) until the
motor performs a short "down" movement.
Tn: Already programmed remote control
A
?
C
Tn
After setting the closing position, open the awning until the necessary opening posi-
tion by pressing the "down" button. You can use the "up"/"down" buttons to precisely
set the opening position (in applications pergolas that allow this, you must press
and hold the button until the motor stops automatically to the maximum opening).
To set the opening position, hold pressed the "stop" button (around 2 sec) until the
motor performs a short "up" movement.
C
TM2 ERY

SETTING OF THE LIMIT SWITCHES

SETTING THE CLOSING LIMIT SWITCH
up
SETTING THE OPENING LIMIT SWITCH
down
Tn
B
Tn (2 sec)
B
Tn (2 sec)
28