GENERAL DESCRIPTION
Your ESS6100 is a professional multifunctional charger with Inverter technology. Designed to support the batteries of demonstra-
tion vehicles or during the diagnostic work, it also guarantees an ideal quality of charge for the maintenance of the most advanced
models. This charger can be fitted with cables up to 8 m long. Changing the charging cables requires recalibration (see page 12).
It is considered a fixed device not a mobile product.
Your ESS6100 is supplied with a software that includes 6 different modes to choose from:
• Charging mode: dedicated to the charging of lead-acid (sealed, liquid, AGM...) or lithium (LiFePO4) starter batteries.
• Power mode | Diag+ : Supplies the energy required during diagnostic work on the vehicle.
• Power mode | Showroom : Maintains the charge of the battery and supplies the energy required when using the consumers
of a demonstration vehicle.
• Power mode | Change Bat. : Allows to keep the vehicle power supply during battery replacement, in order to preserve the
memory of the vehicle's ECUs.
• Power mode | Power supply : Allows the charger to be used as an adjustable stabilized power supply with high power.
• Tester Mode: Used to check the state of the battery and test the vehicle starting system and alternator.
Your ESS6100 is SMART!
The original features of your ESS6100 can be extended by adding specific charging modes and profiles using the USB port and
custom settings (see page 14).
Your ESS6100 also offers the possibility to recover data from several hundred charging operations on your USB stick for analysis on
a spreadsheet.
Additional modules (such as printer, Ethernet port, etc.) can also be connected to the charger via its dedicated module socket.
Auto-Detect» function:
The ESS6100 is equipped with the «Auto-Detect» function which automatically starts a charge
when a battery is connected to the charger. (To enable/disable this function see page 12)
Auto-Restart» function:
The «Auto-Restart» function offers the possibility of automatically restarting the charger in the event of a power failure.
(To enable/disable this function see page 12)
«Lock» function:
It is possible to lock the buttons on your ESS6100 when it is used in a place open to the public or unattended. To activate/deacti-
vate the lock, press and hold
START UP
1. Connect the charger to the mains.
2. Set the switch, located at the back of the charger, to «ON».
3. Select the desired mode (Charge -> Showroom -> Diag+ -> Tester).
To access the «configuration» menu press the
CHARGE MODE
• Setting the mode:
Press the SELECT button for 3 seconds to activate the
1
modification of the mode settings.
2 Use the arrows to change the value of the parameter.
Press the SELECT button to accept the value and move
3
to the next parameter.
MODEL ESS6100
and
for 3 seconds.
key for 3s :
AUTO-DETECT
U=12.3V
Pb-CHARGE
1
liquid
50Ah
2
1- Type of charge
2- Charge profile
3- Rated battery voltage
4- Rated battery capacity
EN
12V
12V
3
4
7