Charge type:
Profil
normal
AGM
water
boost
Pb-CHARGE
recovery+
Easy
Li-CHARGE
LFP/LiFePO4
• Start of the charge:
To start the charge, press the START/STOP button.
1
If the AUTO-DETECT function is active, charging will start
automatically after 5 seconds if a battery is present.
During charge, your ESS6100 indicates the percentage of progress of the
2
charging cycle and alternately the voltage, current, amps hour supplied and
the duration.
3 Press the START/STOP button to stop the charge.
Precautions :
When charging a vehicle, it is recommended to reduce the vehicle power consumption to a minimum (switch off the lights, switch
off the ignition, close the doors, etc.) in order not to disturb the charging process.
Precaution: Check the electrolyte level of any open battery. Fill it up if necessary, before starting the charge.
• Lead-acid charging curve:
1
U
I
Analysis
Recovery
0%
Step 1 : Analysis
Analyses the state of the battery (charge level, polarity inver-
sion, wrong battery...)
8
Charging voltage
2.40 V/cell
2.45 V/cell
2.45 V/cell
2.42 V/cell
2.40 - 2.50 V/cell
2.40 V/cell
3.60 V/cell
2
3
4
Test
Desulfation
10%
MODEL ESS6100
Lead batteries of the types Gel, MF, EFB, SLA...
Most AGM lead-acid batteries including START and STOP.
However, some AGM batteries require a lower voltage charge (Normal profile). Check
the battery manual if in doubt.
Open liquid-type lead-acid batteries with cap.
Maximum current charge for lead-acid battery. This type of charge is ultra-fast.
Warning : this type of charge must remain occasional in order to preserve
battery life.
Charging profile for the recovery of severely damaged lead batteries. It is essential to
recover the battery outside the vehicle to avoid damaging the vehicle electronics and
in a well ventilated area.
Caution: Recovery voltage up to 4.0 V/cell.
Profile dedicated to lead batteries that automatically adapts the charging current
according to the size of the battery.
However, for maximum charge optimization, it is recommended, when possible, to
use normal, AGM or liquid charge curves.
Lithium batteries type LFP (Lithium Ferro Phosphate)
AUTO-DETECT
12V
U=12.3V
5
Charge
20%
Step 6: Absorption
Constant voltage charge to reach 100% charge level.
Pb-CHARGE
U=13.1V
1
Pb-CHARGE
Q=6.7Ah
4
1- Battery voltage
2- Progress of the charging cycle
3- Current delivered by the charger
4- Ampere hours supplied
5- Duration
6
7
Refresh
Absorption
(only for liquid pro le)
80%
95%
EN
24%
2
I=9.7A
3
24%
01h23
5
8
Maintenance/-
Floating charge
100%