Digital Power Meter Model 5000-XT
Bird 5012D, 5016D, 5017D, 5018D, and 5019D Wideband Power
Sensors
Sensor Characteristics
Frequency Range
5012D
5016D
5017D
5018D
5019D
RF Power Range
5012D
5016D
5017D
5018D
5019D
Maximum Power
Impedance, Nominal
Insertion Loss, Max
0.35 – 1 GHz
1 – 4 GHz
Input VSWR, Max
0.35 – 2.5 GHz
2.5 – 4 GHz
Directivity, Min
5012D
5016D
5017D
5018D
5019D
RF Connectors
Interface:
DPM
Power Supply:
DPM
USB Port
DC Connector
58
350 MHz - 4.0 GHz
350 MHz - 4.0 GHz
25 MHz - 1.0 GHz
150 MHz - 4.0 GHz
25 MHz -1.0 GHz
150 mW - 150 W Avg. 400 Watts Peak
25 mW - 25 W Avg. 60 Watts Peak
500 mW - 500 W Avg. 1300 Watts Peak
100 mW - 25 W Avg. 60 Watts Peak
100 mW - 100 W Avg. 260 Watts Peak
Figure 7 on page 61
See
50 ohms
0.05 dB
0.1 dB
1.05:1
1.10:1
30 dB up to 3 GHz,
28 dB from 3 to 4 GHz
30 dB up to 3 GHz,
28 dB from 3 to 4 GHz
28 dB up to 100 MHz,
30 dB from 100 to 1000 MHz
30 dB up to 3 GHz,
28 dB from 3 to 4 GHz
28 dB up to 100 MHz,
30 dB from 100 to 1000 MHz
N Female
Legacy Models: Male DB-9, EIA-232, 9600
baud, no parity, 8 data bits, 1 stop bit
Revision D models: USB
From host instrument via cable
less than one low-power USB load
7 – 18 VDC, < 100 mA