5.3.
Climatic
Reference standard DNV No. 2.4 – 2006
Test specifications
Class: C (-25°C / +55°C)
Standard IEC 60068-2-2
Class: C (-25°C / +55°C)
Standard IEC 60068-2-2
Class: C (-25°C / +55°C / 100% R.H.)
Standard IEC 60068-2-30
5.4.
Vibrations
Reference standard DNV No. 2.4 – 2006
Test specifications
Class: B
Standard IEC 60068-2-6
6. ACCESSORIES
Description
Fuse
Ultra rapid, ceramic, 10 A - 500 V
External potentiometer
10 k - 2 W
7. COMPATIBILITY
MEC-20 M31FA600A
963857154_H
Environmental Phenomena
Dry Heat
Cold
Damp Heat
Environmental Phenomena
Vibration
Code
963823010
963824425
Power Factor
Regulator
M50FA400A
M40FA630A M40FA632A M40FA620A M40FA621A
www.repuestosgruposelectrogenos.es
VARICOMP
M31FA600A MEC-20
Result
Complies
Complies
Complies
Result
Complies
26