GB
X210A.1
X210A.2
X210A.3
X210A.4
X210A.5
X210A.6
X210A.7
X210B.1
X210B.2
X210B.3
X210B.4
X210B.5
X210B.6
X210B.7
1)
Control terminals are freely configurable.
Control "Safe Torque Off" (STO): Contacts on X210A.3 and X210B.2 open ("Low
level").
Release of frequency inverter: Contacts on X210A.3 and X210B.2 closed ("High
level").
86
24 V
ext.
STOA
STOB
Control terminal X210A
Voltage output DC +20 V or input for ext. power supply DC 24 V ±10%
GND 20 V/ GND 24 V (ext.)
Digital Input STOA (first shut-down path)
Digital input
1)
Digital input
1)
Digital input
1)
Digital input
1)
Control terminal X210B
Digital input
1)
Digital input STOB (second shut-down path)
Digital output
1)
MFO1: Multifunction output
frequency, default setting)
Supply voltage DC +10 V for reference value potentiometer, (I
multifunction input
1)
Ground 10 V
Quick Start Guide ACU
X210A
1
+20 V/180 mA
2
GND 20 V
3
S1IND
S2IND
4
5
S3IND
6
S4IND
7
S5IND
M
X210B
1
S6IND
S7IND
2
-
+
S1OUTD
3
-
+
MFO1
V
4
+10 V/ 4 mA
5
MF1
6
GND 10 V
7
Start Clockwise (default setting)
Start Anticlockwise (default setting)
Data Set Changeover 1 (default setting)
Data Set Changeover 2 (default setting)
1)
(voltage signal, proportional actual
(reference speed 0 ... +10 V, default setting)
=4 mA)
max