Descargar Imprimir esta página

Adjustable Parameters - BONFIGLIOLI ACTIVE CUBE Guia De Inicio Rapido

Ocultar thumbs Ver también para ACTIVE CUBE:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

No.
Description
Switching
400
frequency
GB
Min. Switching
401
Frequency
418 Min. Frequency
419 Max. Frequency
Acceleration
420
(Clockwise)
Deceleration
421
(Clockwise)
Op. Mode
452
Multifunction Input
480 Fixed Frequency 1
481 Fixed Frequency 2
Op. Mode Digital
530
Output 1
Op. Mode Digital
532
Output 3
Op. Mode Analog
553
Operation MFO1
Motor Temp.
570
Operation Mode
96

Adjustable parameters

Unit
Higher switching frequencies reduce the motor
Hz
noise, but reduce the output current (refer to
technical data in Operating Instructions)
Frequency to which the switching frequency is
Hz
reduced in case the frequency inverter is
overloaded.
The start command entered via the control unit
or digital inputs S2IND, S3IND results in an
Hz
acceleration of the drive to the minimum
frequency.
The speed range of the drive is limited by the
Hz
maximum output frequency of the frequency
inverter.
The ramps define how quickly the output
Hz/s
frequency is changed if the reference value
changes or after a start, stop or brake command.
The reference value at input MFI1 can be
-
adjusted in this operation mode according to the
connected signal source.
Switching between the fixed frequency values is
done via the fixed frequency change-over of
multifunction input MFI1 (
Multifunction Input
Hz
data record change-over S4IND, S5IND, the fixed
frequency in one of the four data records can be
selected. Up to 8 fixed frequencies can be
parameterized and selected via the control of the
digital inputs.
Various control and monitoring functions can be
-
assigned to digital output S1OUT and relay
output S3OUT.
Output MFO1 supplies a pulse width modulated
-
signal (0 V ... 10 V) which is proportional to an
actual value.
Monitoring the motor temperature protects the
-
drive system. Connect a suitable sensor to digital
input S6IND.
Quick Start Guide ACU
Explanation
Operation Mode
452 to setting 3). Via the
10/18

Publicidad

loading