4

Technical data

Type
General technical data
Protection class to EN 60529
CPX-CP interface fitted completely,
plugs in protection class IP65/IP67
inserted, unused connection fitted with
protective cap
Protection against electric shock
(Protection against direct and indirect
contact as per EN 60204-1/IEC 204)
Load voltage supply of valves (U
Current consumption of CPX-CP interface
(only CPX-CP interface, without CP
modules)
– From operating voltage supply for
electronics/sensors (U
– From load voltage supply for valves
(U
)
VAL
Maximum current consumption per
CP string
– From operating voltage supply for
electronics/sensors (U
– From load voltage supply for valves
(U
)
VAL
Galvanic isolation
– between operating voltage supply for
electronics/sensors (U
voltage supply for valves (U
Festo CPX-CP-4-FB-Z6 1212a English
)
VAL
)
EL/SEN
)
EL/SEN
) and load
EL/SEN
)
VAL
CPX-CP-4-FB
CPX system description
P.BE-CPX-SYS-...
IP65/IP67
By means of a PELV power
supply unit (Protected
Extra-Low Voltage)
Tolerance 20.4 ... 26.4 V
typ. 75 mA at 24 V
typ. 5 mA at 24 V
1.6 A at 24 V
1.6 A at 24 V
None