Diagnostics Messages - La Cimbali S20 Guia De Inicio Rapido

Ocultar thumbs Ver también para S20:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 129

17. Diagnostics messages

There are 2 types of messages that are displayed by the machine:
1. Explicit messages: they appear on the screen accompanied by an explanatory clip or are shown
in the form of an icon in the upper right-hand corner of the display.
2. Coded messages: they are placed in the upper left-hand corner and are represented by the
unit's numerical error code.
If there are several errors, they are represented one after another on the display.
For a detailed description of messages in code, refer to the technical manual, "Defects - Malfunctions"
section.
MESSAGE
CAUSE: when displayed
Machine
1. This message is displayed when the dispensing key is pressed
cold
when:
- service boiler pressure is 0.8 bar less than the setting;
- boiler temperature is 20°C less than the setting.
The
pressure and temperature are reached, it automatically disappears.
2. When the service boiler or boiler respectively cannot reach the
operating pressure or temperature due to a problem, an error code
appears on the display which identifies the defective component
causing the problem.
The
Grounds
coffee based beverages can still be dispensed (10 single or 5 double)
drawer full
before the machine stops.
Empty
The machine counts down from the limit set for grounds. The message
grounds
(along with a film) is shown on the display when it reaches zero. The
drawer
machine is blocked and does not allow any dispensing.
Grounds
This message (along with a film) is always shown when the rear side
drawer
of the drawer is not in place.
removed
Explicit messages
icon represents machine cold status. Once the appropriate
icon informs the user that the grounds drawer is full. Ten
SOLUTION
2. Consult the Technical Manual to find the specific error
code to resolve the problem.
Empty the drawer to clear the message or continue until
the machine displays the message "Empty grounds
drawer".
Refer to the Technical Manual to program the grounds
limit after which the message is displayed.
Remove and empty the grounds drawer. Return the
drawer to its proper position. While carrying out this
operation, the message "grounds drawer removed" will
be displayed.
If the message appears with the drawer inserted, check
that the drawer is properly placed.
26 EN
2
1

Publicidad

Tabla de contenido
loading

Tabla de contenido