Communication ring:
Modem
A maximum of 10 units can be interconnected.
3.3.2. GPRS/3G remote communication via USB modem
1.
Connect the communications card to one of the charging stations located at one end of the installation in
order to start the communication ring. It can be connected both with the J15 and J17 connectors, as well
as the J16 and J18 connectors.
A
Remove the end of line jumper from the control card and connect the charging station to the next station
of the communication ring (dark gray cable in the previous figure).
ABA2017IQM01_B - Installation and Operation Manual
First station
Intermediate station
Ingeteam
Final station
EN