when power is on
2. The blower doesn't
work after pressing the
start bottom.
If after stabilization, it
doest work, there must be
wrong
3. No feeding after 20 seconds of starting.
There are three stages for the feeding process.
One is during the several minutes, feeding is constantly. "Feeding" is showing on the LCD
display
Two is the following couple minutes, the feeding light is off.:"Light" showing on the Display
The last stage is that feeding Every several seconds all the time after previous stages.
A. For the first stage
(during first several
Fuse is broken
It is normal.
It will start automatically
when the temperature is
above 30 degrees on the
venting pipe.
No power in stove or in the
control panel.
Or Unplugged on the mother
board
The low temperature sensor is
broken
Feed unit is blocked.
There is the problem
32
Replace the
fuse
Please wait
Check the power and wires.
Plug it
Replace it
Check the auger is blocked or not.
Check the fasten screw between