Electrical Connections; Operation Testing - Franklin Electric Little Giant 9SC Serie El Manual Del Propietario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATION TESTING

Electrical Connections

Electrical Connections
Risk of severe injury or death by electrical shock.
Always disconnect the electrical power before touching the pump or discharge.
Check local electrical and building codes before installation. The installation must be in accordance
with their regulations as well as the most recent National Electrical Code (NEC).
The flexible jacketed cord assembly mounted to the pump must not be modified in any way, with the
exception of shortening the cord to fit into a control panel. Any splice between the pump and the
control panel must be made within a junction box mounted outside of the basin and comply with the
National Electrical Code. Employ a licensed electrician.
Do not use the power cord for lifting the pump.
Do not remove the third prong from the plug, or cut plug from cord. These actions will void the warranty.
Check the pump label for proper voltage required. Do not connect to voltage other than that shown. Use a
ground fault circuit interrupter (GFCI) if required by code. The pump should be connected or wired to its
own circuit, with no other outlets or equipment in the circuit line. The fuses and circuit breaker should be of
ample capacity in the electrical circuit.
Pump
9SC
10SC
The 9SC-CIA-RF and 10SC-CIA-RF pumps have automatic switches with pig-
gyback plugs on the switch cords. For automatic operation, plug the pump
cord into the float switch cord. Plug the float switch cord (with pump cord
attached) into the GFCI outlet.
OPERATION TESTING
Risk of damage to pump or other equipment.
Do not attempt to run the pump without water; this could result in permanent damage to the pump.
If pump is run dry, it may damage pump and will void the warranty.
If the pump does not operate properly, consult
found, please contact the place of purchase or an authorized service center.
Do not let the unit run dry (without liquid). It is designed to be cooled by pumping fluid. The seal may be
damaged and the motor may fail if the pump is allowed to run dry. Pump should be totally submerged for
proper cooling of the motor when pump is operated for extended periods.
If the unit is going to be idle for a period of time, follow the cleaning instructions outlined in
Impeller and Volute" on page
destroy the unit.
6
HP
Voltage
4/10
115 V
1/2
115V
"Troubleshooting" on page
9. Do not let the unit freeze. This may cause cracking or distortion that may
Breaker Amps
15 A
15 A
9. If the solution still cannot be
"Cleaning

Publicidad

Tabla de contenido
loading

Tabla de contenido