fireguard to be fitted.
•
Use only regulator and hose approved for LP Gas at the correct pressures.
•
The pressure adjuster should comply with the standard EN12864 and
current regulations in the country where it is installed,which may be
found at your nearest retailer of gas items,Refer to the technical date.It is
strictly prohibited to use adjustable pressure.
•
The life expectancy of the regulator is estimated as 10 years.It is
recommended that the regulator is changed within 10 year of the date of
manufacture or the national conditions require it.
•
The type of replaceable hose should meet the standard of EN1763-1
Class 3.
•
The hose used must conform to the relevant standard for the country of
use. The length of the hose must be 0.5 m (maximum).Worn or damaged
hose must be replaced. Ensure that the hose is not obstructed,kinked,or
in contact with any part of the appliance other than at its connection. It
is recommended that the hose is changed within 1 year of the date of
manufacture or the national conditions require it.
Your heater consumes oxygen while it is in use. For this reason, adequate
ventilation should be provided in rooms in which the heater is used. This
ensures the removal of products of combustion and allows the entry of
replacement air.
Adequate ventilation should considerably reduce condensation occurring. The
following table shows the smallest sizes of room suitable for each heat setting
and the ventilation, which should be provided.