CONNECTING THE CYLINDER
1. Place the gas filled cylinder into the back of the heater.
2. Clip on the gas regulator to the gas cylinder,connect the regulator to
flexible tubing and the valve.
3. Turn the cylinder and the regulator on.
4. Where the regulator is not supplied or is missing please contact your gas
dealer to advise of the correct type for the gas cylinder being used.
Important test for leaks
This must be carried out in a well ventilated area, free from naked flames and
any other sources of ignition. With the regulator connected to the cylinder
turn on the regulator control. Brush all hose connections, pipe connections
to the valve and gas cylinder with a 50:50 solution of detergent and water or
a leak detection spray. A stream of bubbles forming indicates a leak.
If a leak is found turn off at the regulator and disconnect the regulator from
the bottle and remove the gas cylinder outdoors or to a well ventilated area.
Contact your gas supplier for assistance. DO NOT USE THE HEATER..
Fix the rear cover after leakage test.
WARNING
Danger of Explosion
Never use an open flame to check for leaks.
How to change a cylinder
1. Turn off at the regulator and allow the heater to cool fully before
removing and replacing the cylinder. Do not attempt to replace the
cylinder whilst the heater is still in use.
2. Cylinders must be replaced in a flame free environment.
3. Do not smoke while changing the cylinder
4. When you need to replace your empty cylinder, turn the gas off at the
valve or regulator and take the empty cylinder out of the heater.
5. Remove the regulator from the empty cylinder.
6. Follow the steps described under "Connecting the Cylinder", connect a
new cylinder.