en
50 | CRS 845H | Calibrating the high-pressure rail
8.7
Recording measured values
1. Open the "Report" menu by pressing <F2>.
2. Select the "Restart test" menu.
3. Call up the "Measurement functions" selection
menu with <F7>.
4. Select the "Automatic on/off" menu option and
press <F12> to switch on the automatic function.
The Automatic symbol in the operating status
display flashes.
The system moves to the set values and the
waiting time or measuring time starts. After the
waiting time or measuring time has elapsed, the
system software automatically changes to the
next test step.
5. When the message "
System being halted! No
more test steps! Results with F12 >>.
appears, press <F12> to open the report.
6. Print out the report by pressing <F3> and "Print".
i
If printout is not possible, make a note of the mea-
sured values on a sheet of paper.
8.8
Saving calibration values
i
From EP software version 2011/A onwards, the mea-
sured values are taken on automatically. Up to EP
software version 2011/A, the measured values must
be transferred manually.
1. Exit from the "Result printout" dialog window
with <Esc>.
2. In the "Injection component test main menu" start
screen select <F7>
A password request appears.
3. Enter the password in the input line:
4. Confirm the entry with <F12>.
5. Select the menu item Calibration >> Rail pressure
sensor.
The measured values obtained in Section 8.7
have automatically been entered in the boxes for
Test bench pressure value, Test bench press.val.
upst.of filter and External pressure value.
6. Input Save with <F4>.
The calibration date is updated.
|
1 689 978 535
2014-10-21
8.9
1. In the "Rail pressure sensor calibration" window,
press <F6>.
The calibration value check is now active.
2. Press <F12> to save.
3. Quit the menu by pressing <Esc>.
The system software reinitializes the devices.
4. In the "Injection component test main menu" start
screen select <F12>.
Displaying legal information. (Page 1 of 2)
5. Read legal information carefully and adhere to under
all circumstances.
6. Continue with <F12>.
Displaying legal information. (Page 2 of 2)
7. Read legal information carefully and adhere to under
"
all circumstances.
8. Continue with <F12>.
9. Press <F2> to open the "Database" menu.
10. Press <F12> to select the "New component" menu
option.
11. In the Type number field enter the numbers
0445020105 .
12. Press <F2> to open the "Database" menu.
13. Press <F12> to select the "Search for components"
menu option.
The "Component selection Local database"
window is displayed.
14. Select test routine for pressure sensor check
0445020105 C1 and open with <F12>.
15. Call up the "Measurement display" window
with <F12>.
The "Attention" dialog box opens with the maxi-
mum speed.
16. Continue with <F12>.
The measurement display opens.
1958
Starting check
Robert Bosch GmbH