12. SYNCHRONIZATION OF TWO MODULES IN THE
SAME CAN NETWORK
When you have two modules working on the same CAN network, in order for
the events to be displayed correctly in both of them, it is necessary to perform
a synchronization by means of a flash drive. To perform the operation, proceed
as follows:
- Choose one of the devices to manually save the settings and/or
devices that will later be copied to the other MG3000 (we will call this device
"Master" and the secondary one "Slave").
- Perform the settings and save them. In the case of recording new
devices, register and update the receivers normally before starting the procedu-
re. After the process in the "Master" MG3000 is finished, insert the flash drive
in it, access the programming menu ("BASIC MENU"), and select "BACKUP"
[Figure 12.a]. Make the backup on the flash drive and wait until the backup confir-
mation message is displayed [Figure 12.b]. Press "BACK" to complete the action
and remove the flash drive.
- Insert the flash drive in the "Slave" MG3000, access the "RESTORE" option
in the "ADVANCED MENU" [Figure 12.c], select the corresponding backup file,
identifying it by the label that was recorded with the "Master" MG3000 time, date
and SUPPORT labels at the time of backup [Figure 12.d]. Perform data resto-
ration, tap the "HOME" button, press the "NO" key, and remove the flash drive
[Figure 12.e]. After performing this procedure, the events generated by the acti-
vation of registered devices must appear in the two modules.