Fault Messages - Bosch CRI/CRIN 848H Manual Original

Juego de comprobación para la comprobación de inyectores de rail común
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 145
7.

Fault messages

System malfunctions are displayed by fault messages
on your screen.
2054 CRI UBAT too small
Example
The fault message can be cleared by acknowledging
with the <F12> key. It will appear again however, if the
fault has not been rectified.
The following table lists all fault messages, with remedi-
al measures, which could occur when testing common-
rail injectors If "KD" is listed in the remedial measure
column then notify Bosch After Sales Service with de-
tails on the message number. This also applies to mes-
sage numbers which are not listed in the table.
i
For all fault queries to the After Sales Service the
status code and module ID must be stated for faster
fault clearance.
Status
Module ID
Information
code
2039
CRI
Watchdog communication dis-
rupted!
2040,
CRI
Injector X not adaptable or
2042,
faulty!
2044,
(Fault notified only after in-
2046,
jector actuation duration of ≥
2048,
250 µs)
2050
2041,
CRI
Injector X short circuit
2043,
-or-
2045,
Injector A/C/E short circuit
2047,
-or-
2049,
Injector B/D/F short circuit
2051
2052
CRI
Overvoltage UC on injectors
A/C/E!
2053
CRI
Overvoltage UC at injectors
B/D/F!
2054
CRI
Voltage UBAT too small
2055
CRI
Voltage UBAT too large
2056
CRI
Tolerance error for internal
voltage 3.3V
2057
CRI
Tolerance error for internal
voltage 12V
2058
CRI
Tolerance error for internal
voltage UCP
2059
CRI
Tolerance error for internal
voltage VC
2064
CRI
CRC fault on interface
Robert Bosch GmbH
Fault messages | CRI/CRIN 848H | 95
Remedial measures
Check whether voltage stabilizer is switched on.
Check whether supply lines are plugged in.
Check whether RS 232 connecting cable is plugged in.
Check whether current limiting on voltage stabilizer  28 A is set
Check whether adapter cable on injector X is connected.
Replace injector X.
Replace injector X.
Check whether the connecting cable is defective (short circuit).
Check whether a disconnected connection cable caused a short-circuit.
Check whether actuation parameters in system software at "Gen. values"
have been correctly set.
Check whether actuation parameters in system software at "Gen. values"
have been correctly set.
Check whether the correct injector voltage has been set on the voltage sta-
bilizer
Check whether the correct injector voltage has been set on the voltage sta-
bilizer
KD
KD
KD
KD
KD
en
|
1 689 989 087
2018-07-24

Publicidad

Tabla de contenido
loading

Tabla de contenido