6.4 Measuring ranges

Chlorine Cl
2
Chlorine dioxide ClO
0 to 2 mg/l; 0 to 20 mg/l*
2
Ozone O
3
0 to 14 pH; 2 to 12 pH;
pH
5 to 9 pH
0 to 1000 mV;
Redox
0 to 1500 mV
Pt100
-5 to +120 °C
*
For O
the actual measuring range is limited to 0
3
to 5 mg/l.

6.5 Factory settings

General factory settings
Current output
Controller
®
Conex
DIS-D
Measuring range
Type of measuring cell
Water sensor
®
Conex
DIS-PR
Sensor system
Measuring range
Temp. measurement
Water sensor
Further default values, see section
overview.
6.6 Dimensions
105
55,5
®
Fig. 2
Conex
DIS
8
0 to 20 mA
Off
0 to 2.00 mg/l
AQC-D3/-D13
Off
pH
0 to 14 pH
Off, manual temperature
compensation
Off
9.4 Code
72,5
10
160,5
59
165,5