3.1 DETECTION DISTANCE ADJUSTMENT
The faucet activates or deactivates by placing the hand closer than 5 cm. (default setting). This distance
can be changed for installation requirements or user prefrerences.
This adjustment is only possible within the first 2 minutes after power supply connection
1
Unplug and plug the power
supply. Within the first 2 minutes,
proceed with the following steps.
4
When the red LED of sensor starts
to blink, remove hand. The water
flow will stop, if it was open.
7
x1
< 2 cm
After 5 sec. the red LED turns off
and the detection distance is set
to the new value (2-10cm). If the
hand is not placed or if it was re-
moved from the sensor before 5
seconds, the faucet will be set
to the longest detection distance
(10cm).
WARNING: depending on the placement of the faucet and the handling of objects surrounding it, it is possible to expe-
rience involuntary detections. If that happens, reduce the detection distance or adjust the water flow delay time (See 3.2).
2
x1
The LED blinks one time. Wait 5
sec. to start the adjustment pro-
cess.
5
x1
< 2 cm
After 3 sec. the faucet starts wa-
ter flow and the red LED blinks 1
time per sec. during 5 sec. Within
those 5 sec. place hand in fornt of
sensor closer than 2cm. The red
LED remains lit and the water flow
stops.
9
3
< 2 cm
Place hand in fornt of the sensor
closer than 2cm. for 5 sec. regard-
less of water flow.
6
2-10 cm
Place the hand to the desired dis-
tance, between 2 and 10 cm. and
keep in place for 5 sec.