PEDESTRIAN START INPUT FUNCTION
This is the same as the preceding function, but the
connection with the WIRED DIGITAL SELECTOR
(TTNC) or the IDENTIFICATION UNIT (VRD) is
made on the PEDESTRIAN START input.
Cont
the PEDESTRIAN START input is enabled
for the connection of control devices with
normally open contact.
Cod
the PEDESTRIAN START input is enabled
for the connection TTNC or VRD.
CODE TYPES (WHEN ENABLED) ON THE START
AND PEDESTRIAN START INPUTS
This function is only active when either one of the
inputs, START or PEDESTRIAN START, are
enabled to the code mode:
tiP.A
if you are using the identification unit
(VRD), select this mode.
tiP.b
if you are using the wired digital selector
(TTNC), select this mode.
IMPORTANT: If you are using a VRD on an
input and a TTNC on the other input, or both in
parallel on one input, select code tiP.A anyway.
INPUT STOP
This menu permits to select the functions
associated to the command of STOP.
no
the input STOP is not available
invE
the command STOP stops the gate: at the
next START the gate starts moving in the
opposite direction.
ProS
the input STOP stops the gate: pressing
the command START the gate continues
the motion.
NOTE: During the pause STOP stops the gate:
pressing the command START will always
re-closing the gate.
38