REPA MILLENNIUM V8 BASIC PLUS AS Manual De Instrucciones página 18

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

4) MANUAL STARTING PROCEDURE OF REGENARATION
Based on customer requirements, a regeneration process can be started manually at any time. In this case, you will notice
that, during the regeneration process, the softener will deliver unsoftened water.
To proceed with manual regeneration, follow the steps below:
Press and hold the buttons at the same time
Press the button
and immediately the regeneration process will start.
2.2.6 SECTION FOR TECHNICAL PERSONNEL
It is possible to access the programming of the regeneration times in the various phases.
Changing these settings defined by the manufacturer seriously compromises the functionality of the softener, so please do
not do so.
If these settings have been changed by the customer, you can reset the original data as follows:
REGENERATION CONTROL MODE
FREQUENCY OF COUNTER-CURRENT WASHING
QUANTITY OF SOFTENED WATER
WASHING TIME COUNTER-CURRENT
BRINE ASPIRATION TIME/WASH
BRINE TANK FILLING
FAST WASHING
MAXIMUM REGENERATIVE INTERVAL (IN DAYS)
OUTPUT MODE
18
for 5 seconds until you hear the beep and the key pad is unlocked.
m
m
m
m
m
A – 01
F – 00
Millennium 8 (0.55)
Millennium 12 (1.10)
2 – 01
3 – 20 (Millennium 8)
3 – 40 (Millennium 12)
4 – 04 (Millennium 8)
4 – 06 (Millennium 12)
5 – 03
H - 03
b - 01

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido