PROBLEM
The switch light remains off.
The panel light doesn't turn on
after the machine has been on for
several minutes
The
sealing
process
normally, but the light remains
green
The
unit
heats,
but
process is not sufficient
.
DANGER: HIGH INTERNAL VOLTAGE. DO NOT DISASSEMBLE.
CHAPTER 7
7.1 - PROBLEM SOLVING GUIDE
CAUSES
No voltage/electrical current
Protection fuses on the side of the
cable
Switch light broken
Panel broken
The light doesn't function
The power unit is not heating
occurs
Micro Switch broken
Sealing
pressure
sealing
sufficient
Silicon rubber ruined
SOLUTION
Check electrical supply
Check for possible short circuit or
breakage, if so replace with fuses
of the same value
Replace the switch fuses set
There may be a fault with the
electronic board. Send the unit to
BA or an approved service centre
for repair.
There may be a fault with the
light. Send the unit to BA or an
approved
repair.
There may be a fault with the
power unit. Send the unit to BA or
an approved service centre for
repair.
Send the unit to BA or an
approved
repair.
is
not
Check the screws which support
the silicon rubber piece.
Send the unit to BA or an
approved
repair.
13
service
centre
for
service
centre
for
service
centre
for