Now it is possible to set up the time, the day of the week, the date and
the year, following the instructions.
1
Exact time
Par
Description
1
Time
a) Push the line selection buttons to select line 1.
b) Push the
buttons to set up the time.
The time on the timer is set up according to the exact time. This set-
ting is important to ensure that the heating program of the regulator
will work correctly.
2
2)
Day of the week (actual)
Par
Description
2
Day of the week
a) Push the line selection buttons to select line 2.
b) Push the
buttons to set up the day of the week.
The timer will be set on the selected day of the week.
1 = Monday
5 = Friday
2= Tuesday
6 = Saturday
3 = Wednesday
7 = Sunday
4 = Thursday
3
3)
Date (Day, Month)
Par
Description
3
Date (Day, Month)
a) Push the line selection buttons to select line 3.
b) Push the
buttons to set up the day and the month.
The setting up of the date is important to ensure a correct
Summer/Winter and Winter/Summer switching.
4
4)
Year
Par
Description
4
Year
a) Push the line selection buttons to select line 4.
b) Push the
buttons to set up the year.
Time of the system
In those systems where the regulators communicate through a bus
system, the time and the date can be set on any regulator and they
are automatically updated on all the others.
NOTE: The setting of the date and that of the day of the week are not
connected. This means that when the set date is, let's say a
Wednesday, Wednesday must also be set at Parameter 2.
2.2. 1
Installer Level
The configuration and set–up of the parameters must be carried out
by a heating engineer.
Among the possible display and set–up options there are:
– The recognized installation Type (53)
– The actual value of the zone delivery temperature (55)
– The actual value of the A.C.S. temperature (56) (only if connected
to a boiler card)
– The actual value of the boiler temperature (57) (only if connected
to a boiler card)
– Maximum limit for pre–ignition (73)
Set up field
U/M
00:00...23:59
Hour : Minutes
Set up field
U/M
1...7
Day
Set up field
U/M
01:01...31:12
Day Month
Set up field
U/M
1999...2099
Year
– Maximum limit for pre–switching off (74)
– Zone delivery temperature setpoint (63)
– Maximum limit of delivery temperature setpoint (69), useful for
floor installations.
– Reduced setpoint of A.C.S. temperature (80) (only coupled with a
boiler card)
Please refer to Point 11 for a complete list of the parameters.
Buttons
Explanation
PUSH ONE OF THE LINE SELECTION BUTTONS.
1
THIS WILL LEAD YOU DIRECTLY TO THE "END
USER" PROGRAMMING MODE.
PUSH BOTH THE LINE SELECTION BUTTONS
FOR AT LEAST 3 SECONDS. THIS WILL LEAD
YOU DIRECTLY TO THE "INSTALLER"
3s
PROGRAMMING MODE.
PUSH THE LINE SELECTION BUTTONS
3
TO SELECT A LINE
PUSH THE "+/–" BUTTON TO SET UP THE
DESIRED VALUE. THE SET VALUE WILL BE
4
STORED WHEN YOU QUIT THE
PROGRAMMING MODE OR MOVE ON TO
ANOTHER LINE.
TO QUIT THE "INSTALLER" PROGRAMMING MODE,
PUSH ONE OF THE BUTTONS OF
THE WORKING MODE.
5
If no button is pushed for 8 minutes,
the control device will return automatically to the
last selected working mode.
2.2. 1
Manufacturer Level (OEM)
It is the level reserved to the boiler's manufacturer.
If we attribute the number 1 and 2 to the two "Prog" buttons and the
number 3 and 4 to the two buttons next to them, the resulting
access code will be "12434"
1
2
Please refer to Point 12 for a complete list of the parameters.
We highly recommend not to modify the OEM settings!
Buttons
Explanation
PUSH ONE OF THE "UP/DOWN" SELECTION
1
BUTTONS. THIS WILL LEAD YOU DIRECTLY TO THE
"END USER" PROGRAMMING MODE.
9s
PUSH BOTH THE LINE SELECTION BUTTONS
2
FOR AT LEAST 9 SECONDS.
PUSH THE
AND
TO INSERT THE REQUIRED ACCESS CODE.
IF THE BUTTON COMBINATION IS CORRECT YOU
YOU WILL SWITCH TO THE OEM
3
CODE
PROGRAMMING MODE.
IF THE INSERTED CODE WAS WRONG,
THE DISPLAY WIL SWITCH TO "SETTINGS PARAMETER
FOR THE INSTALLER".
PUSH THE SELECTION BUTTONS TO SELECT
4
THE DESIRED LINE.
PUSH THE "+/–" BUTTON TO SET UP
THE DESIRED VALUE.
5
THE SET VALUE WILL BE STORED WHEN
YOU QUIT THE PROGRAMMING
MODE OR MOVE ON TO ANOTHER LINE.
TO QUIT THE "OEM" PROGRAMMING MODE,
PUSH ONE OF THE BUTTONS
OF THE WORKING MODE.
6
If no button is pushed for 8 minutes,
the control device will return automatically
to the last selected working mode.
Line
1
51
51...98
3
4
Line
1
°°
BUTTONS
1.....91
69