Wiring diagram
QAA 70
ponticello Albatros
inserito
D6 D5 D4 D3 D2 D1
SB
SB
SE
SE
–
SCHEDA
CR
+
CR
CALDAIA
TA
TA
L
N T
L
N
T
ALBATROS RVA46.531
VM
N
L
3.4. 1
Parameter setting
For the regulator to be able to recognize this installation you need to
set the following parameters as shown in the table.
ZONE 1:
mixing valve, pump, zone feeler and room unit
Installation ID
– Setting mode = USER
(refer to the "Parameter setting levels" paragraph)
Par
Description
17*
Heating curve slope
* According to the installation type
– Setting mode = INSTALLER
(refer to the "Parameter setting levels" paragraph)
Par
Description
69*
Max. limit of delivery temp. setpoint
85
LPB–equipment address
87
Operation with timer
* According to the installation type
ZONE 2:
pump and room unit
Installation ID
– Setting mode = UTENTE
(refer to the "Parameter setting levels" paragraph)
Par
Description
17*
Heating curve slope
* According to the installation type
UA1
+
–
LPB BUS
SE
SZ
–
+
–
+
PZ1
KEY
SE
External feeler (QAC31)
UA
Zone room unit (QAA70)
1–2–3
PZ
Zone pump
1–2–3
Default values
Setup
15
15
Default values
Setup
80
70
0
0
Default values
Setup
15
15
Non invertire la polarità della connessione
QAA 70
UA2
D6 D5 D4 D3 D2 D1
+
–
–
+
–
+
ALBATROS RVA46.531
PZ2
SZ
Zone feeler (QAD21 / QAZ21)
VM
3–way mixing valve
TMAX Thermostat for excess temperature
– Setting mode = INSTALLATORE
(refer to the "Parameter setting levels" paragraph)
Par
Description
67
Room temperature differential
69*
Max. limit of delivery temp. setpoint
85
LPB–equipment address
87
Operation with timer
* According to the installation type. In pump–operated circuits, the room unit
is necessary in order to avoid excess temperatures.
ZONE 3: mixing valve, pump, zone feeler, excess temperature
thermostat and room unit (floor installation)
Installation ID
– Setting mode = UTENTE
(refer to the "Parameter setting levels" paragraph)
Par
Description
17*
Heating curve slope
* According to the installation type
1
3
– Setting mode = INSTALLATORE
(refer to the "Parameter setting levels" paragraph)
Par
Description
69*
Max. limit of delivery temp. setpoint
85
LPB–equipment address
87
Operation with timer
* According to the installation type
3.4.2
Verifying the correct recognizing
To make sure the regulator has correctly recognized the installation
QAA 70
UA3
D6 D5 D4 D3 D2 D1
+
–
SZ
–
+
–
+
ALBATROS RVA46.531
TMAX
VM
PZ3
Default values
Setup
––.–
80
0
0
Default values
Setup
15
Default values
Setup
80
0
0
1
70
2
2
7.5
37
3
2
75