Installation examples

The smoke evacuation system is essential for correct chimney operation. Make sure that the installed chimney has at least one
inspection hatch located in an easily accessible point to aid cleaning.
Chimneys in poor conditions can only be used by inserting a regulation smoke duct inside them (see standards on ducting).
MIN 1 m
External air intake
MIN 1 m
External air intake
Use and maintenance manual Chronos, Zeus, Ercole e Ermes
MIN 1 m
External air intake
Protection from rain
Insulated pipe
Insulated chimney
Insulated T fitting for
condensation
If the fitting to the chimney is horizontal, it
is necessary to not insert the last section of
pipe too far, to avoid throttling the smoke.
Any free thickness between the hole in the
existing chimney and the smoke duct pipe
must be duly sealed.
MIN 1 m
External air intake
Rev.1 12/12/2019
Page 65
NO
YES
MAX 2m
slope min 3%