1) Important! Programming the hc10 – start here!
Important! Start here, by setting the clock and day of the week.
‹ Press [P] and acknowledge with [OK]
‡ The hours on the time display will flash
‹ Use [Ç] or [Å] to set the hour figure.
‹ Press [π]
‡ The minutes on the time display will flash
‹ Use [Ç] or [Å] to set the minute figure
‹ Press [π]
‡ WORKDAY 1 will flash
‹ Use [Ç] or [Å] to set the day of the week. Workday1 = Monday, workday 2 = Tuesday etc.
‹ Confirm by pressing [OK]
2) Setting the functions and altering the programs
2.1) Set hc10 to floor sensor
‹ Press [·] for approx. 4 secs.
‡ (FL), (RO) or (CO) will flash on the display
‹ Press one of the arrow keys [Ç] or [Å] until (FL) shows on the display
‹ Confirm by pressing [OK]
The underfloor heating will now be controlled by the signal from the floor sensor. The
display will show the temperature the floor will reach.
Note: The temperature shown on the display will typically be lower than the room
temperature.
2.2) Setting hc10 to room sensor
The use of room sensor is recommended if there is no floor sensor in the floor.
‹ Press [·] for approx. 4 secs
‡ (FL), (RO) or (CO) will flash on the display
‹ Press one of the arrow keys [Ç] or [Å] until (RO) shows on the display
‹ Confirm by pressing [OK]
The underfloor heating will now be controlled by the signal from the room sensor. The
display will show the temperature the air in the room will reach.
2.3) Setting hc10 to combined room and floor sensor
Note: This setting is used when using the heating under a timber floor
‹ Press [·] for approx. 4 secs
‡ (FL), (RO) or (CO) will flash on the display
‹ Press one of the arrow keys [Ç] or [Å] until (CO) shows on the display
‹ Confirm by pressing [OK]
The thermostat is now set to combined floor and room sensor.
The choice of combined room and floor sensor activates monitoring of the temperature in
the floor. Temperature monitoring is set at the factory to max. +27°C and min. +15°C.
By using the floor sensor, hc10 will now ensure that the floor temperature*) is never higher
than + 27°C nor lower than + 15°C. These values can be adjusted as desired.
*) Temperature measured by floor sensor.
Limiting the maximum temperature in the floor is important when the heating is installed
under a timber floor. Leading suppliers of timber floors prescribe a maximum temperature
of 27°C on the surface of their floors.
Find out what the supplier of your timber floor recommends. Set the maximum value to the
prescribed temperature.
3) Setting hc10 to operate night and day setback.