9) Read out present floor temperature
Applicable only when floor sensor is connected.
‹ Press [·]
‡ Present temperature is shown in the display for 10 sek. I.e. FL :22
10) Switching between display of 24 hour clock and am/pm format.
‹ Press [π] and hold it in. While holding in [π] , press [OK]. This will switch between 24
hour clock and am/pm.
11) Turning hc10 on and off
‹ Press [Ç] and [Å] simultaneously.
hc10 will turn off
‹ Press any key to turn hc10 on again
12) Resetting hc10
This procedure will return Heat Control 10 to Quickstart. Any changed values in night and
day setback will be lost.
‹ Press simultaneously [ P ][·][Ç][Å]
‡ The display will go out and then everything will turn on again
hc10 has now been reset.
F) Position, installation and connection
F.1) Position and connection of floor sensor
Position of floor sensor in the room.
Position the floor sensor about 0.5 m from the wall.
Position the floor sensor near the hc10. This gives the simplest installation.
If desired, the floor sensor cable can be extended.
Optional extension of floor sensor cable
Use ordinary doorbell cable to extend the floor sensor cable. Maximum extension 9m.
Position of floor sensor on floor.
Position the floor sensor in a pipe approximately half-way between two heating cables.
If necessary, the sensor may be placed in a grouting gap, without the use of cables.
When positioning in a grouting gap, any regrouting should be undertaken with care in order
not to damage the sensor.
Connection of floor sensor.
Connect the floor sensor to the hc10 as shown on the diagram.
F.2) Position and mounting of hc10
Important! hc10 must not be covered.
¸ If the floor sensor (FL) is used, any position may be used.
¸ If the room sensor (RO) or combined room and floor sensor (CO) are used, hc10 must
be positioned approximately 1.2 m above the floor.
Avoid:
¸ Heat from radiators, wood-burning stoves and other heaters
¸ Cold outer walls
¸ Concealed pipes or chimneys which give off heat
¸ Direct sunlight or positioning behind curtains
Installation can be carried out in two different ways:
¸ Flush-mounted in the wall
¸ Surface-mounted on the wall
Selection of installation box for flush mounting
For walls of wood, plasterboard etc, use flush-mounting box (53000003)
For walls of brick, concrete etc., use flush-mounting box (53000002)
Selection of installation box for surface mounting
When mounting on the surface of a wall, use surface-mounting box (53000001).
9