English
Application
Fingerprint module as access control
system with function LED.
Suitable for:
• Stand-alone operation
• Up to 100 user fingerprints
• Up to 5 user groups
• Not backwards-compatible with
the FPM 611-02
The FPM 600-... fingerprint module
in the Vario design is an access
control system used in stand-alone
mode (as an independent system).
In this system, a scanned fingerprint
is used to actuate a function (such as
a door release).
Up to max. 100 users (scannable fin-
gerprints) can be managed in each
operating mode.
Electrical voltage
Mounting, installation and servicing
work on electrical devices may only
be performed by a suitably qualified
electrician.
Pilfer safeguard
In order to protect the Vario modules
from unauthorized access, the pilfer
safeguard controller DSC 602-... can
be optionally used in conjunction
with the ZDS 601-... This can be
used to protect the inserted modules
from unauthorized access.
Scope of supply
• Fingerprint module FPM 600-...
• Terminal block
• This product information
Conductor material
Telecommunication or light current
conductors can be used for instal-
lation:
J-Y(St)Y
Twisted pair conductors,
shielded
A2Y(St)2Y Buried telecommunica-
tion cable
Terminal assignment
cv, bv
Power supply 12 V AC
S1, S2
n.o. contact 24 V, 2 A
Mounting
• Plug in ribbon cable with combina-
tion terminal
• Insert the FPM 600-... in the
mounting frame
1 Terminal plan for standalone
operation
Specifications
Operating voltage: 12 V AC,
12–30 V DC
Operating current: 120 mA AC,
70 mA DC
Contact type: contact 24 V, 2 A
Switching time: 3 sec
Protection system: IP 54
Ambient temperature:
–20 °C to +55 °C
Height of structure (mm): 17
Dimensions (mm) W x H x D:
99 x 99 x 43
Commissioning
Initialisation
The device starts up automati-
cally as soon as power is supplied.
Alternately flashing left LED (green)
and right LED (red) indicate that the
device is starting up. This generally
takes about 10 seconds.
After initialisation, the device
switches to one of three states:
A) Ready for operation
B) Teach-in mode
C) Error status
A) Left LED (green) is lit continu-
ously: Startup OK; fingerprints have
already been taught-in: Ready for
operation.
B) Left LED (red) is lit continuously:
Startup OK; fingerprints have not yet
been taught-in: Teach-in mode.
C) Left LED (red) and right LED (red)
flash: Incorrect startup (e.g. incor-
rect address, hardware fault): Error
state.
Important notes
• Set the required operating
mode before commissioning the
FPM 600-...
• If you adjust the rotary switch for
setting the operating mode, ALL
taught-in fingerprints are deleted.
• Individual administrator, master
and user fingerprints cannot be
deleted. Administrator and master
fingerprints can only be removed via
delete mode. User fingerprints can
also be deleted during operation as
a group or ALL together.
• In some cases, it can happen that
a fingerprint cannot be scanned due
to absence of biometric characteris-
tics. In this case, try using a different
finger. This applies primarily to
children and older people. In these
cases, it is also possible that a finger-
print will not be recognised.