using the key PARAMETERS to enter the process parameters menu. Turn knob 2 to select the parameter, press it to
enter the adjustment screen and turn it to adjust the value.
To adjust connection time, crater filling current and crater filling time values, enter the main menu by selecting
key F MENU and use key
Turn knob 2 to select the parameter, press it to enter the adjustment screen and turn it to adjust the value.
Mode 4T�
To begin welding, press and release the torch trigger; to stop welding press and release it again. Together with Mode
4T you can also select function HSA (automatic hot start) and function CRA (final crater filling). (See Mode 2T).
Mode 3L�
Particularly recommended for welding aluminium. The HSA and CRA functions are inhibited when mode 3L is activa-
ted. Three welding currents can be selected using the torch trigger. The current and the connection time values are
set as follows:
Start Current. Adjustable from 10 to 200% of set welding current.
Connection Time. Adjustable from 0.1 to 10 seconds. Defines the connection time between start current and wel-
ding current and between welding current and crater filling current (crater filling when welding is complete).
44/58
Press the DEF key to restore factory settings.
After activating the parameter CRA , the operator can adjust connection time between
the welding current and the crater filling current from 0.1 to 10 seconds.
The operator can also adjust the crater filling current from 10 to 200% of the welding
current.
The duration of this current can also be adjusted from 0.1 to 10 seconds of the crater
filling time.
PARAMETERS to enter the process parameters menu.
Press the DEF key to restore factory settings.