ELECTRICAL CONTROL AND POWER SUPPLY*
§
pal-turn™ is equipped with a switch box for protecting the
motor and the user (except 1 model).
§
Remote control with cable or cordless on
request.
§
The standard cable button box is connected on
the control box of the load turnover system
through a "harting" type six-contacts connector.
The end-user can easily ensure connection of
the pal-turn™ control on the one of the lifting
device (connection on site not provided by
Tractel Solutions) using this available "harting"
type connector.
§
The cable for power supply is separated and can be connected either on the floor or on the
lifting device.
§
Electrical supply through three-phase network (3 phases + 1 earth connection).
§
The turnover can be single- or double-speed. (optional)
Standard IP54 electrical protection index (protection against dust: no noxious deposit ;
§
protection against water ejections from all directions)/other index on request.
Use with a remote control, an infrared transmitter or other:
See the manufacturer manual for the instructions appropriate for this material.
* Electrical drawings are attached at the end of this document.
Storage
▪
Correctly store the straps, in good conditions, and instructions for use with the pal-turn™.
▪
Keep the material in a dry place, protected from bad weather.
▪
Ensure that the pal-turn™ is stored with no loads attached.
▪
Store with the pulleys symmetrically positioned as close as possible to the pal-turn
avoid imbalance.
ü
Maintenance
Maintenance inspections and operations must be performed by qualified persons and specialists.
§
Any deformed equipment must be immediately withdrawn from use.
§
Specially check conditions of straps. In case of wearing out of the straps, you must imperatively
contact TRACTEL SOLUTIONS SAS so that it provides exactly the same straps according to
recommendations.
Regularly check the equipment is in perfect working order.
§
Check the functioning of the material and visually inspect the straps before any use.
§
§
Any part with a defect must be replaced by a TRACTEL SOLUTIONS SAS part.
§
The gear motor should be drained every 4 years.
TRACTEL SOLUTIONS accepts no responsibility when inappropriate straps are used.
M 6067 M
rev 10 – 07/2020
GB
STORAGE AND MAINTENANCE
Control
box
connector
X
Cable
for
power supply
body to
TM
Page 26/92
www.tractel.com