Generally, heating operation is possible also without fan
regardless of operating mode (gas or additional heater)�
However, in order to ensure that the warm air is distrib-
uted evenly and quickly and to lower the surface tem-
perature of the cover, we recommend that you operate
the S-heater/Ultraheat with the fan running and a warm
air system at all times�
If the Ultraheat additional heater is operated with a re-
mote sensor*, the sensor must not be placed near other
heat sources (cookers, lamps, opposite warm air outlets
etc�) or in locations where heat can accumulate (below
shelves, in corners, behind curtains)�
4.5

Control panel

1
Ultraheat
Ultraheat
2
2000
2000
500
500
1000
1000
230 V ~
Fig� 3
The rotary switch (Fig� 3-2) is used to switch the elec-
tric additional heater on an off and to adjust the heat-
ing output� A green LED (Fig� 3-4) beneath the rotary
switch is lit when the electric additional heater has
been switched on� The control knob (Fig� 3-1) is used to
adjust the room temperature� The temperature level is
shown on a scale of 1 to 9�

The temperature setting on the control panel (1 – 9)
must be determined individually depending on heat-
ing requirements and the type of vehicle�
For temperature control, the room temperature is meas-
ured with a temperature sensor in the control panel
(Fig� 3-3)�
Symbol
Function
2000
Additional heater is heating with
2000 watts
OFF
Additional heater is off
500
Additional heater is heating with 500 watts
1000
Additional heater is heating with
1000 watts
4.6

Accessories*

Extension cable for control panel, 5 m
(part no� 34300-01)
The FFC 2 room temperature sensor, complete with
4 m connection cable (part no� 34203-01), monitors
the room temperature regardless of the position of
the control panel�
30090-00229 · 00 · 06/2021
Ultraheat
3
2000
500
1000
230 V ~
5

Start-Up

During the initial start-up of a brand new appliance,
small quantities of fumes and a slight odour may occur
briefly�
When the appliance is started up, especially after a long
period of non-use, there may be some fumes and/or
smell due to dust or dirt for a short time�
Make sure the room is well ventilated�
If necessary, switch on the S-heater fan�
To allow a self-cleaning process, operate the addi-
tional heater at its highest operating level for a few
minutes�
6

Operation

Before switching on, make sure that the set oper-

ating level corresponds to the fuse of the campsite
4
power supply (refer to "Technical Data")�

To ensure that warm air is distributed throughout the
vehicle quickly and evenly, we recommend that you
always operate the heater with the fan running�

In electrical mode, operate the fan at least at level 3
(manual or automatic)�
6.1

Switching on Ultraheat

Set the rotary switch to the desired heating power
500, 1000 or 2000�
The green LED is lit and also indicates the selected
temperature setting�
Set the desired temperature level 1 - 9 on the con-
trol knob�
6.2

Switching off Ultraheat

Set the rotary switch to
The green LED is off�
7

Faults

Listed below are some actions that can be taken to rec-
tify faults� If these actions do not produce the desired
result, contact Truma Service�
Ultraheat is switched on but the green LED in the
control panel remains off.
Possible cause: No 230 V power supply�
Check 230 V power supply�
Are other 230 V appliances in the vehicle
working?
Is the line power cable connected?
Has the fuse in the line power connection (fuse-
box at campsite) blown?
Has the RCCB (residual current circuit-breaker) in
the 230 V vehicle distribution board tripped?
Has a fuse in the 230 V vehicle distribution
board blown?