Installation Instructions
Indoor unit installation
1. Installing the Mounting Plate
FOR the Ordinary Mounting Plate
Decide an installing location for the mounting plate according to the indoor unit location and piping
direction.
Note: it is recommended to install screw anchors for sheet rock, concrete block, brick and such type of wall.
Keep the mounting plate horizontal with a horizontal level or dropping line.
.
Mark the center of the indoor unit on mounting plate for future reference.
Note: the center of the mounting bracket may be not the center of the indoor unit.
Tapping mounting plate to the wall with a minimum of five screws, evenly spaced to properly support
indoor unit weight.
Tapping screw
Note: The shape of your mounting plate may be different from the one above, but the installation method is similar.
Note: As the above figure shown, the six holes matched with tapping screw on the mounting plate must be used to
fix the mounting plate, the others are prepared.
MOUNTING BRACKET DIAGRAMS AND DIMENSIONS (Recommended)
50mm/2in
or more to wall
Mounting plate
200mm/7.9in or more to ceiling
For 738 Series Model, WIDTH:522mm/20.6in
For 808 Series Model, WIDTH:592mm/23.3in
8
Indoor unit outline
50mm/2in
or more to wall
Pipe hole