Installation Instructions

Site Instructions

Site for Installing Indoor Unit
Where there is no obstacle near the air outlet and air can be
easily blown to every corner.
Where piping and wall hole can be easily arranged.
Keep the required space from the unit to the ceiling and wall
according to the installation diagram on previous page.
Where the air filter can be easily removed.
Keep the unit and remote controller 1m(3.28ft) or more apart from
television, radio etc.
keep as far as possible from fluorescent lamps.
Do not put anything near the air inlet to obstruct it from air
absorption.
Install on a wall that is strong enough to bear the weight of the unit.
Install in a place that will not increase operation noise and vibration.
Keep away from direct sunlight and heating sources. Do not place
flammable materials or combustion apparatuses on top of the unit.
Site for Installing Outdoor Unit
Where it is convenient to install and well ventilated.
Avoid installing it where flammable gas could leak.
Keep the required distance apart from the wall.
Keep the outdoor unit away from greasy dirt, vulcanization gas exit.
Avoid installing it by the roadside where there is a risk of muddy
water.
A fixed base where it is not subject to increased operation noise.
Where there is not any blockage of the air outlet.
Avoid installing under direct sunlight, in an aisle or sideway,
or near heat sources and ventilation fans. Keep away from
flammable materials, thick oil fog, and wet or uneven places.
In case the pipe length is more than 7.5m(24.6ft), the refrigerant should be charged additionally, according
to below table.
If the height or pipe length is out of the scope of the table, please consult the merchant.
Model
9K-18K
24K
30K-36K
Indoor unit is higher than outdoor unit
20 meters(65.4ft) Max.
Indoor unit
Outdoor unit is higher than indoor unit
Required amount of
additional refrigerant (g/m)
20
30
40
7
Indoor unit
Pipe length is
20 meters(65.4ft) Max.
Outdoor unit
Outdoor unit
Pipe length is